Hot search:
 

Over-voltage Under-voltage Relay

Click on the image to check the artwork
unit price: negotiable
min amount:
amount:
period for delivery: Consignment Deadline Days
area: Zhejiang
Expiry date : Long Effective
last update: 2018-11-14 13:06
view count: 446
enquiry
Company Profile
 
 
Product details

Applications

Used in air conditioning units, elevator machine room, pumps, fans and other motor control applications, as protection of over-voltage. Uunder voltage, phase failure, phase sequence, phase imbalance and PTC temperature. When the power supply is abnormal, turn off power supply to protect the equipment.


Features:

Built-in microprocessor, true RMS measurement, measurement accuracy≤1%. 50/64Hz universal, knob setting, LED indicator shows working status. Withe N-phase phase failure protection, unique load-side and PTC temperature protection, optional manual reset and key test function, DIN rail mounting.


Model Description


Model Selection Table

Model

Over-voltage

Under-voltage

Unbalance

Phase sequence

Phase failure

Reset

Test

PTC Protection

Load protection

ZHRV1

Setting range

Delay range

Setting range

Delay range

Setting range

Delay range

01

1.05...1.30

0.1s...10s

-

-

-

-

-

+

-

-

-

-

02

-

-

0.70...0.95

0.1s...10s

-

-

-

+

-

-

-

-

03

1.05...1.30

0.1s...10s

0.70...0.95

0.1s...10s

-

-

-

+

-

-

04

1.05...1.30

0.1s...10s

0.70...0.95

0.1s...10s

-

-

+

+

-

-

05

1.05...1.30

0.1s...10s

0.70...0.95

0.1s...10s

8%

2s

-

+

-

-

06

1.05...1.30

0.1s...10s

0.70...0.95

0.1s...10s

8%

2s

+

+

-

-

07

1.05...1.30

0.1s...10s

0.70...0.95

0.1s...10s

5%...15%

0.1s...10s

-

+

-

-

08

1.05...1.30

0.1s...10s

0.70...0.95

0.1s...10s

5%...15%

0.1s...10s

+

+

-

-

09

1.05...1.30

2s

0.70...0.95

2s

8%

2s

-

+

-

-

10

1.05...1.30

2s

0.70...0.95

2s

8%

2s

+

+

11

1.15

2s

0.85

2s

5%...15%

0.1s...10s

-

+

12

1.15

2s

0.85

2s

5%...15%

0.1s...10s

+

+

13

1.15

2s

0.85

2s

8%

2s

-

+

14

1.15

2s

0.85

2s

8%

2s

+

+

15

1.15

2s

0.85

2s

-

-

-

+

16

1.15

2s

0.85

2s

-

-

+

+

-

-

-

-

17

-

-

-

-

5%...15%

0.1s...10s

+

+

-

-

-

-

18

-

-

-

-

-

-

+

+

-

-

-

-

19

-

-

-

-

8%

2s

+

+

-

-

-

-


Note:

1. "+"Function is available, "-"Function is not availble. "○"Function can be customized.

2. In three-phase four-wire circuit, relay without phase sequence protection could acheive sigle-phase or two-phase protection.

3. Choose either PTC protection or load protection.

4. Load protection: L1/L2/L3(P-P).


Technical Parameters

Rated supply voltage

AC220V、AC230、AC240V、AC380V、AC400V、AC415V

Rated supply frequency

50Hz/60Hz

Over-voltage threshold range

(1.05~1030) ×Ue

Under-voltage threshold range

(0.70~0.95) ×Ue

Unbalance threshold range

5%~15%

Action delay range

0.1s~10s

Phase failure and phase sequence

≤1s

Voltage measurement error

≤1%(Entire setting range)

Delay error

±10%+0.1s

Knob setting accuracy

±1% Scale value

Rated insulation voltage

415V

Contact configuration capacity(A)

10A

IP Class

IP20

Class of pollution

3

Electrical Life

105

Mechanical life

106

Altitude

≤2000m

Allowable relative humidity

≤50%(40℃)(No condensation)

Use category

AC-15

Short circuit protector type

RT36-00 5A

Contact capacity

Ue/le:240V/1.5A,415V/0.95A

Output type

1C/O

DIN rail Standard

(width)35mm (IEC/EN60715)


Function diagram


Wiring Diagram


Dimensions(mm)


Model significance:

ZHRV1-04/A380 voltage relays, rated coltage AC 380V with phase failure, phase sequence, over-voltage protection. Adjustable over-voltage range(1.05-1.3)Ue, under-voltage range(0.7-0.95)Ue, unbalance protection range(5%-15%)Ue, action delay time 0.1s to 10s.